⚠️ Inverex Inverter Error Codes — Complete Troubleshooting Guide Pakistan 2026
Every Inverex error code explained with cause, severity and step-by-step fix. Covers Nitrox hybrid (Deye platform) and Aerox/Veyron (Voltronic platform) — two different code families. Save this page — it is the fastest way to diagnose your Inverex problem.
📅 Updated November 2026 | 🇵🇰 Pakistan | ⚡ Nitrox • Aerox • Veyron
📋 In this guide
1. How to Read Inverex Error Codes
Read this first — Inverex uses two completely different code families, and mixing them up leads to wrong fixes. Nitrox inverters are built on the Deye platform and use F-codes (F01–F64). Aerox, Veyron and Axpert King models are Voltronic-based and use plain numeric codes (01–59) with no F prefix. The same number means different things across families — Nitrox F07 is a blown GFDI fuse, while Axpert 07 is an overload timeout. Always match the code to your exact model.
- Critical faults: Safety or hardware failures — the inverter has stopped and must be inspected before any restart. Do not keep resetting these.
- Warning codes: Grid or environmental readings outside the normal band — most disappear by themselves when conditions return to normal.
Nitrox codes run F01–F64 only — no codes above F64 exist in the Nitrox/Deye scheme. If a guide lists F65 or higher for a Nitrox, it is wrong. On newer Voltronic models (Axpert MAX/Ultra) the same numeric faults display with an F prefix (F01 = fan abnormal) — a third numbering that must not be confused with the Nitrox F-codes.
2. Nitrox Critical Fault Codes
| Code | Name | Severity | Common Cause in Pakistan | Fix |
|---|---|---|---|---|
| F01 | DC input polarity reverse fault | Critical | PV strings wired +/− reversed during installation or after panel work | Switch off DC, verify string polarity with a multimeter, correct the MC4 connections before re-energising. |
| F02 | DC insulation impedance permanent fault | Critical | Damaged PV cable insulation, water ingress in rooftop junction boxes during monsoon, rodent-chewed DC cable | Isolate strings one at a time to find the faulty string; inspect/replace damaged DC cabling; dry out junction boxes; retest. |
| F03 | DC leakage current fault (GFDI failure) | Critical | PV +/− shorted to earth, wet/damaged panels, faulty earthing | Check PV array earthing and insulation; disconnect strings to isolate the leak; repair damaged modules/cables. |
| F04 | Ground fault GFDI (battery and grounding) | Critical | Poor or missing earth, battery grounding fault, damp battery room | Verify earth electrode and battery grounding; check battery cable insulation; dry and re-terminate connections. |
| F07 | GFDI blown fuse | Critical | Ground-fault current blew the GFDI fuse (often after a lightning surge or earth fault) | Find and clear the underlying earth fault first, then replace the GFDI fuse — never just reset. |
| F15 | AC overcurrent fault (software) | Critical | Surge load on backup output (motor starting — water pump, AC compressor), grid surge | Reduce backup load; stagger motor starts; check for shorted appliances; restart. |
| F24 | DC insulation impedance failure | Critical | PV +/− to earth resistance too low — monsoon damp, cracked panels, degraded DC cable | Measure string insulation resistance; isolate and repair the affected string. |
| F26 | DC busbar unbalanced | Critical | Lost phase or poor connection; possible internal hardware damage | Check all AC/DC connections; if connections are sound, contact dealer — likely hardware. |
| F55 | DC busbar voltage too high | Critical | PV input voltage too high (too many panels in a string, cold-morning Voc spike) or battery voltage too high | Check PV string Voc against the inverter's max DC input; reduce panels per string; check battery voltage/charging settings. |
| F56 | DC busbar voltage too low | Critical | Battery deeply discharged after long load shedding, or battery disconnected/fuse open | Charge battery from PV or grid; check battery breaker, fuse and cable connections. |
3. Nitrox Grid & Warning Codes
| Code | Name | Severity | Common Cause in Pakistan | Fix |
|---|---|---|---|---|
| F13 | Working mode change (hybrid) | Warning | Grid type/frequency setting changed, or battery mode switched to 'No battery'; also reported on some firmware when work mode changes | Usually clears automatically; if persistent, switch DC and AC off for 1 minute, then restart. Note: this meaning is hybrid-only — on 3-phase string models F13 is 'Reserved'. |
| F34 | AC overload fault | Warning | Backup load exceeds inverter rating (common when grid fails and heavy appliances stay on) | Shed load to within the inverter's rated output; split heavy loads off the backup circuit. |
| F35 | No AC grid | Warning | Load shedding, tripped main breaker, loose grid connection, DISCO outage | Confirm grid is actually present; check breaker and AC wiring; inverter auto-reconnects when grid returns. |
| F36 | AC grid phase error / phase sequence fault | Warning | Wrong phase sequence on 3-phase supply (common after meter or transformer work by DISCO) | Have an electrician swap two phases at the inverter AC input to correct sequence. |
| F41 / F43 / F45 | AC line over voltage (W-U / V-W / U-V) | Warning | High grid voltage — common at night in low-load areas, or near a lightly loaded transformer | Verify with a multimeter; if grid is genuinely high, report to DISCO; inverter reconnects when voltage normalises. |
| F42 / F44 / F46 | AC line low voltage (W-U / V-W / U-V) | Warning | Low grid voltage / brownouts — very common in Pakistan, overloaded transformers, long feeders | Check voltage at the meter; report persistent undervoltage to DISCO; consider a stabiliser on the grid side only if installer advises. |
| F47 | AC over frequency | Warning | Grid frequency above limit (unstable DISCO supply, generator input) | Check grid/generator frequency; if on generator, stabilise its speed; inverter reconnects when frequency normalises. |
| F48 | AC low frequency | Warning | Grid frequency below limit during load shedding / grid stress | Same as F47 — verify supply frequency; no user fix if the grid itself is unstable. |
| F58 | BMS communication fault | Warning | Loose/faulty CAN/RS485 cable between inverter and lithium battery, wrong BMS protocol setting | Reseat the BMS comm cable, check port and protocol setting; restart battery then inverter. Note: BMS meaning is hybrid-only — on 3-phase string models F58 means AC grid overcurrent. |
| F64 | IGBT heatsink high temperature | Warning | Inverter in direct sun or unventilated room in 45 °C+ summer heat, blocked heatsink/dust | Move/shade the inverter, improve ventilation, clean heatsink with a soft brush; switch off 10 min to cool, then restart. |
4. Voltronic Numeric Codes (Aerox / Veyron / Axpert King)
These plain numeric codes (no F prefix) apply to Voltronic-based Inverex models — Aerox, Veyron and Axpert King. If your inverter shows a number without an F prefix, use this table, not the Nitrox tables above.
| Code | Name | Severity | Common Cause in Pakistan | Fix |
|---|---|---|---|---|
| 01 | Fan locked | Warning | Cooling fan blocked by dust or failed — very common in Pakistan's dusty environment | Clean the fan and vents; restart once; if it persists, the fan motor needs replacement. |
| 02 | Over temperature | Warning | Inverter overheating — direct sun, unventilated room, 45 °C+ summer heat | Shade the inverter, improve ventilation, clean vents; switch off 10 min to cool, then restart. |
| 03 | Battery voltage too high | Critical | Battery voltage above the inverter's limit — wrong battery type or charging settings | Check battery-type setting; installer must verify battery/inverter compatibility. |
| 04 | Battery voltage too low | Warning | Battery deeply discharged after long load shedding | Charge battery from PV or grid; check battery connections and breaker. |
| 05 | Output short circuited | Critical | Short circuit on the AC output — faulty appliance or wiring | Switch off all loads, check wiring and appliances one by one; do not restart until the short is found. |
| 06 | Output voltage too high / abnormal | Critical | Output voltage out of range — internal fault or grid surge | Restart once; if it persists, contact dealer — likely hardware. |
| 07 | Overload timeout | Warning | Backup load exceeded the rated output for too long | Reduce the load on the backup output; move heavy appliances off the backup circuit. |
| 08 | Bus voltage too high | Critical | Internal DC bus voltage too high — PV input or battery voltage issue | Check PV string voltage and battery voltage; restart once; if it persists, contact dealer. |
| 09 | Bus soft start failed | Critical | Internal soft-start circuit failed | Restart once; if it persists, contact dealer — hardware fault. |
| 51 | Over current | Critical | Output current too high — overload or short circuit | Reduce load; check for short circuits; restart. |
| 52 | Bus voltage too low | Critical | Internal DC bus voltage too low — battery or PV input issue | Check battery voltage and PV connections; restart once; if it persists, contact dealer. |
| 53 | Inverter soft start failed | Critical | Inverter failed to start up — internal fault | Restart once; if it persists, contact dealer — hardware fault. |
| 55 | Over DC voltage in AC output | Critical | DC component in AC output too high — internal fault | Restart once; if it persists, contact dealer — hardware fault. |
| 56 | Battery connection open | Warning | Battery disconnected — loose cable, open breaker, or blown fuse | Check battery cables, breaker and fuse; reconnect firmly. |
| 57 | Current sensor failed | Critical | Internal current sensor fault | Restart once; if it persists, contact dealer — hardware fault. |
| 58 | Output voltage too low | Critical | Output voltage below range — overload or internal fault | Reduce load; restart once; if it persists, contact dealer. |
| 59 | PV voltage over limitation | Critical | PV input voltage above the inverter's max — too many panels per string | Reduce panels per string so Voc stays below the inverter's max DC input. |
5. Most Common Inverex Problems in Pakistan
🔴 Problem: F35 (No AC grid) several times a day
Completely normal in Pakistan — F35 is simply the inverter reporting load-shedding. The inverter auto-reconnects when the grid returns. If F35 appears while the grid is live, check the main breaker and AC wiring connections.
🔴 Problem: F58 (BMS communication fault) on a Nitrox hybrid
The most common Nitrox hybrid problem in Pakistan — almost always the CAN/RS485 cable between inverter and lithium battery, or the wrong BMS protocol setting. Reseat the cable, check the port and protocol setting, then restart the battery and then the inverter.
🔴 Problem: F34 (AC overload) every time the grid fails
When the grid drops, all backup-circuit loads switch to the inverter at once — and heavy appliances (AC, geyser, water pump) exceed its rating. Fix: split heavy loads off the backup circuit so only essential loads (lights, fans, fridge, TV) run on backup.
🔴 Problem: Code 07 (overload) on Aerox/Veyron
On Voltronic-based models, code 07 means the backup load exceeded the rated output for too long. Reduce the load immediately — running overloaded damages the inverter. Note this is NOT the same as Nitrox F07 (GFDI fuse), even though the number matches.
6. First-Response Checklist — Any Inverex Error
- Identify your model first — Nitrox (F-codes) or Aerox/Veyron/Axpert King (numeric codes) — then look up the code in the right table
- Note the exact error code displayed on screen — write it down before doing anything else
- Check if the error appeared during load-shedding, heavy rain, extreme heat, or a dust storm — these are the most common Pakistan triggers
- For grid codes (F35, F41–F48): wait for the grid to stabilise — most self-clear automatically
- Power cycle the inverter: DC isolator off → AC circuit breaker off → wait 3 minutes → AC on → DC on
- For F01–F04, F07, F24 (polarity, insulation, ground faults) — stop here, do NOT power on again. Call your installer immediately
- If the inverter is within warranty, contact your authorized Inverex dealer with the error code, model number, serial number, and a photo of the display
Frequently Asked Questions
Pehle: apna model check karo — Nitrox hai ya Aerox/Veyron? Phir screen pe error code dekho. DC isolator band karo, AC breaker band karo, 3 minute ruko, phir AC on karo, phir DC on. Agar code F35 hai (no grid): ye aksar load-shedding ki wajah se hota hai aur grid wapas aate hi khud theek ho jata hai. Agar F01 ya F02 hai: bilkul mat chalao — installer bulao.
Nitrox inverters use Deye-platform F-codes (F01–F64), while Aerox, Veyron and Axpert King use Voltronic numeric codes (01–59) with no F prefix. The same number means different things — Nitrox F07 is a blown GFDI fuse, Axpert 07 is an overload timeout. Always match the code to your exact model.
F35 (No AC grid) is the most common Inverex alarm in Pakistan — it simply means the grid dropped, which is load-shedding. The inverter auto-reconnects when power returns. If F35 appears while the grid is live, check the main breaker and AC wiring.
F58 means the inverter lost communication with the lithium battery. Reseat the CAN/RS485 cable between inverter and battery, check the port and BMS protocol setting, then restart the battery and then the inverter. Note: the BMS meaning is hybrid-only — on 3-phase string models F58 means AC grid overcurrent.
It depends on your model. On Aerox/Veyron/Axpert King (Voltronic), code 07 is an overload timeout — reduce the backup load. On Nitrox, F07 is a blown GFDI fuse — find and clear the underlying earth fault first, then replace the fuse. Never just reset either one.
📚 Related Guides
Need Help with Your Inverex?
If error codes persist after following this guide, get help from a verified Inverex installer in your city.
🔧 Find Inverex Installer 📖 Inverex Review