Your inverter is flashing a code and the manual is a PDF in another language. This hub links every error-code guide on inverterhybrid.com — eight brands, roughly one hundred verified codes, each one checked against the manufacturer's own manual and explained for Pakistani homes.
📅 Updated November 2026 | 🇵🇰 Pakistan | ⏱️ 6 min read
Pick your inverter brand below. Every guide lists the code, what it means in plain language, how serious it is, and the fix — starting with the checks you can safely do yourself.
100–125 & SPH/SPF faults
Growatt error codes 100 to 125 plus SPH hybrid and SPF off-grid fault codes, with the fixes that work on Pakistani grid conditions.
E01–E32 & battery alarms
GoodWe E-codes explained from the official manuals, including E15 grid failure, E19 over-temperature and the PV Master battery alarms.
SUN2000 alarms 2001–2068
Huawei SUN2000 alarm IDs from 2001 to 2068, plus LUNA2000 battery module faults, with Huawei’s own Major and Minor severity ratings.
SH/SG codes 002–714
Sungrow SH hybrid and SG on-grid codes, from grid faults 002 and 010 to insulation fault 039 and battery fault 703.
RHI & S6 fault codes
Solis RHI hybrid and S6 series fault codes, including grid, PV input and battery communication faults.
State codes incl. 509
Fronius state codes explained, including the frequently searched state 509, with the checks to run before calling a technician.
Nitrox F-codes & Voltronic 01–59
Inverex Nitrox F-codes and the separate Voltronic numeric codes used by Aerox, Veyron and Axpert King models — two different systems.
SUN hybrid F01–F64
Deye SUN hybrid F-codes from F01 to F64, including the model-dependent F42 low-voltage code that trips up many owners.
Most error codes are the inverter protecting itself, not a sign that it has died. Before you panic, work through these steps in order — they resolve a surprising number of faults.
If your inverter keeps reporting grid faults — codes like Growatt E15, Huawei 2032 or Sungrow 010 — the inverter is usually not broken. Pakistan's grid voltage swings far wider than the narrow band inverters are designed for, especially during load-shedding recovery, when voltage can spike as feeders come back online. Inverters disconnect to protect themselves, log a grid fault, and reconnect when the voltage settles.
A grid fault that appears once during a storm or a load-shedding cycle is normal behaviour. A grid fault that appears every day at the same time points to a local voltage problem worth reporting to your DISCO, or to an inverter whose grid-code settings were never configured for Pakistan. Either way, the fix is rarely a new inverter.
One caution: the voltage thresholds quoted in many online guides come from Australian or European standards and do not apply in Pakistan. Our brand guides avoid quoting foreign thresholds as if they were local rules.
Call a qualified solar technician — not a general electrician — when any of these apply:
When you call, have the exact code, the inverter model, and the time the fault first appeared ready. A technician who hears "F58 on a Nitrox 6kW, started yesterday evening" can arrive with the right parts; one who hears "it shows an error" cannot.
What should I do first when my inverter shows an error code?
Write the code down exactly, check the grid supply, PV isolator and battery breaker, then restart the inverter once after a five-minute wait. If the code clears and does not return, it was most likely a transient grid or sensor event. If it returns, look it up in the brand guide above.
Can I reset an inverter error code myself?
A single power-cycle restart is safe and clears most transient codes. What you should not do is repeatedly reset a code that keeps returning, or open the inverter casing — the DC side stays live and dangerous even with the display off. Persistent codes need a technician.
Why does my inverter show grid errors during load-shedding?
When power returns after load-shedding, grid voltage often surges outside the inverter's safe band. The inverter disconnects to protect itself and logs a grid fault, then reconnects once voltage stabilises. Occasional grid codes around load-shedding are normal; daily repeats at the same time suggest a local voltage problem.
Are Inverex and Deye error codes the same?
Yes, for the Nitrox series: Inverex Nitrox inverters are built by Deye, so the Nitrox F01–F64 codes are the Deye codes. But Inverex also sells Voltronic-based models (Aerox, Veyron, Axpert King) that use plain numeric codes 01–59, where the same number means something completely different. Check which family your model belongs to before trusting a code table.
Where do your error-code meanings come from?
From the manufacturers' own manuals and official fault lists — 53 sources across the eight brands. Where a code's meaning could not be confirmed in a manual, the guide says so instead of guessing, and where online guides contradict the manuals, the manuals win.
Send us the exact code and your inverter model on WhatsApp and we will point you to the right guide.
WhatsApp Us — 0315-4616192