⚠️ Deye Inverter Error Codes — Complete Troubleshooting Guide Pakistan 2026
Every Deye SUN hybrid error code explained with cause, severity and step-by-step fix. Covers SUN single-phase and three-phase hybrid series. Save this page — it is the fastest way to diagnose your Deye problem.
📅 Updated November 2026 | 🇵🇰 Pakistan | ⚡ SUN-3K • SUN-5K • SUN-8K • SUN-12K
📋 In this guide
1. How to Read Deye Error Codes
Deye SUN hybrid inverters show fault codes as F-numbers (F01–F64) on the LCD screen and in the monitoring app. The fault list runs F01–F64 only — codes F65–F99 do not exist in any Deye manual or fault list, so any guide listing them is wrong.
- Critical faults: Safety or hardware failures — output has stopped and the unit needs inspection before restarting. Do not keep resetting these.
- Warning codes: Grid or environmental readings outside the normal range — most resolve automatically once the grid or temperature settles.
Model warning — F42 means two different things: on single-phase hybrids (SUN-3/5/6K-SG03LP1, SG04LP1), F42 is AC line low voltage — very common in Pakistan. On three-phase hybrids (SUN-5/6/8/10/12K-SG04LP3), F42 is a Parallel Version Fault (parallel inverters running mismatched firmware), and low voltage is F44/F46 instead. Always match the code to your exact model and the full fault name shown on the LCD. Deye does not publish severity labels — the severities below are editorial judgement (Critical = inverter stops producing or a safety risk; Warning = usually self-clearing or grid-side).
2. Critical Fault Codes
| Code | Name | Severity | Common Cause in Pakistan | Fix |
|---|---|---|---|---|
| F01 | DC input polarity reverse / DC_Inversed_Failure | Critical | PV string +/− wires swapped at install or after rewiring; new installs and panel additions | Switch off DC/AC, verify string polarity with a multimeter before reconnecting; never swap MC4s live. If wiring is correct, contact Deye support. |
| F02 | DC insulation impedance permanent fault | Critical | Monsoon moisture, cracked/damaged PV cable insulation, water in MC4 connectors or junction boxes | Check PV array is not grounded; test PV-to-earth insulation resistance; dry/replace damaged cables and connectors; installer-level megger test if it persists. |
| F03 | DC leakage current fault / GFDI_Failure | Critical | Earth leakage from wet/damaged PV wiring, poor earthing, dusty panels washed with water reaching connectors | Check PV grounding and insulation impedance; check leakage current; dry out connectors; if it persists, contact Deye support. |
| F08 | GFDI_Relay_Failure | Critical | Neutral–earth bonding fault — common in Pakistan where the backup-load neutral is not bonded to earth, or loose N/PE wiring | In split-phase/three-phase systems the backup-load port N line must be connected to ground; check N/PE wiring; if it persists, contact support. |
| F18 | AC over current fault of hardware | Critical | Backup load exceeds rating — water pump, AC compressor or motor starting surge during load shedding; short circuit on load side | Check backup + common load power is within range; reduce load (stagger motor starts); restart and check; if it recurs at low load, contact support. |
| F20 | DC over current fault of the hardware | Critical | Large load started in off-grid/battery mode (pump, AC), or PV/battery wiring fault | Check PV and battery connections; reduce load power; off-grid, start heavy loads one at a time; power-cycle DC/AC after 1 minute. |
| F23 | AC leakage current transient over current | Critical | Sudden leakage-current spike — wet PV array after rain, damaged cable touching the frame, faulty earthing | Check PV-side cable ground connection; restart system 2–3 times; if it persists, get an insulation test — do not ignore recurring trips. |
| F24 | DC insulation impedance failure | Critical | PV isolation resistance too low — monsoon damp, morning dew, dust + moisture on panels, damaged MC4s | Check panel-to-inverter connections are firm and correct; verify inverter PE cable is earthed; dry and re-test; professional insulation test if recurring. |
| F34 | AC Overcurrent fault / AC_Overload_Fault | Critical | Backup output overloaded — too many appliances on the UPS/load output during load shedding; motor inrush | Check backup load is within the allowed power range; move heavy loads (geyser, AC) off the backup output; restart. |
| F55 | DC bus voltage too high | Critical | PV string voltage too high — Voc rises on cold, bright winter mornings in northern Pakistan; string too long for the model | Check battery voltage is not too high; check PV input voltage is within the allowed range (re-check string Voc at minimum temperature); shorten the string if over the max DC voltage. |
| F56 | DC busbar voltage too low | Critical | Battery deeply discharged after long load shedding, weak/failing lithium cell, loose battery cables, BMS limiting discharge | Check battery voltage; charge the battery from PV or grid; check battery cable connections and BMS discharge limits; check voltage under load, not just SOC. |
| F58 | BMS communication fault | Critical | Lithium battery CAN/RS485 cable loose, wrong pinout (ordinary Ethernet cable), wrong battery protocol selected, battery/BMS switched off, wrong DIP-switch/master setting | Check BMS cable and port (use the battery maker's cable, not a plain LAN cable); confirm correct protocol and DIP switches; confirm battery is on; if 'BMS_Err-Stop' is active, communication loss stops the inverter — fixing the link is the real fix. |
| F64 | Heat sink high temperature failure | Critical | Pakistan summer heat (45–50 °C), inverter installed in direct sun or a closed, unventilated room, blocked vents/fan | Check ambient temperature; move/shade the inverter out of direct sun; ensure ventilation clearance; turn off for 10 minutes and restart; clean vents. |
3. Grid & Warning Codes
| Code | Name | Severity | Common Cause in Pakistan | Fix |
|---|---|---|---|---|
| F13 | Working mode change / Grid_Mode_changed | Warning | Grid type or frequency changed, battery mode switched to 'No battery', or settings changed (common after load-shedding mode changes and firmware updates) | Usually clears automatically. If it stays: turn off DC and AC switches, wait 1 minute, turn back on; check no settings were changed unintentionally. |
| F35 | No AC grid / No Utility | Warning | Load shedding (the most common cause in Pakistan), tripped AC breaker, loose grid connection, missing phase | Confirm whether grid power is actually out; check the breaker between inverter and grid is on and connections are firm; inverter resumes automatically when grid returns. |
| F42 | AC line low voltage (single-phase only) | Warning | Pakistan's chronic low grid voltage (often 170–200 V in summer evenings) drops below the inverter's limit | Check AC voltage is within spec; check AC cables are firm and correctly connected; if voltage is genuinely low, it is a utility (DISCO) issue — do NOT widen protection limits without approval. Note: on three-phase models F42 means Parallel Version Fault instead — low voltage there is F44/F46. |
| F43 | AC_VW_OverVolt_Fault (three-phase) | Warning | Grid voltage spikes above limit — common during light-load hours and after load-shedding restoration | Check voltage is within spec; check AC cables are firm; if overvoltage is frequent, report to the DISCO; persistent cases need installer support. |
| F44 | AC_VW_UnderVolt_Fault (three-phase) | Warning | Low grid voltage on one or more phases, especially in summer peak hours | Check voltage is within spec; check AC cables; if the supply is genuinely low, it is a utility issue. |
| F47 | AC over frequency | Warning | Grid frequency above 50 Hz limit, or unstable generator frequency | Check frequency is within spec; check AC cables; with a generator, check its speed/governor stability under load. |
| F48 | AC under frequency | Warning | Grid frequency sag during load shedding/restoration, or generator slowing under heavy load | Check frequency is within spec; check AC cables; on generator, reduce load and check frequency stability. |
4. Warnings & Other Codes
These codes are less common but relevant to Pakistani installs — fan warnings in dusty conditions, generator faults, and parallel-system messages.
| Code | Name | Severity | Common Cause in Pakistan | Fix |
|---|---|---|---|---|
| W02 | FAN WARN (fan warning) | Warning | Fan abnormal — dust-clogged or failed cooling fan, very relevant in dusty, hot Pakistani installs | Check fan operation and its connection; clean the fan and vents; if the warning persists, the fan needs replacement. |
| F60 | Gen_Volt_or_Fre_Fault (generator fault) | Warning | Generator voltage/frequency out of range — relevant since generators are common backup in Pakistan | Check generator voltage/frequency, then restart. Stabilise the generator's speed/governor under load. |
| F26 | BusUnbalance_Fault | Warning | DC bus unbalanced — can be triggered by large load differences between phases (three-phase) or DC leakage | Wait, check phase balance, restart 2–3 times; if it persists, contact support. |
| F29 | Parallel_CANBus_Fault | Warning | Parallel communication fault — appears briefly at parallel-system startup and clears when all units are ON | Check parallel cable and inverter addresses; if it appears only at startup and clears, it is normal. |
5. Most Common Deye Problems in Pakistan
🔴 Problem: F35 (No AC grid) several times a day
Completely normal in Pakistan — F35 is simply the inverter reporting load-shedding. The inverter resumes automatically when the grid returns. If F35 appears while the grid is live, check the breaker between inverter and grid is on and the connections are firm.
🔴 Problem: F42 (low voltage) every summer evening
Pakistan's chronic low grid voltage — often 170–200 V in summer evenings — drops below the inverter's limit. Check the AC voltage with a meter; if it is genuinely low, it is a DISCO issue to report. Do NOT widen protection limits without approval. (Single-phase models only — on three-phase models F42 means something else entirely.)
🔴 Problem: F58 (BMS communication fault) on a hybrid system
The most common Deye hybrid problem in Pakistan. Check the BMS cable and port first — use the battery maker's cable, not a plain LAN cable — then confirm the correct protocol and DIP switches, and confirm the battery is switched on. If "BMS_Err-Stop" is active, communication loss stops the inverter; fixing the link is the real fix.
🔴 Problem: F64 (heatsink high temperature) in summer
Pakistan's 45–50 °C summers push inverters mounted in direct sun or closed rooms past their limit. Move or shade the inverter, ensure ventilation clearance, clean the vents, and switch off for 10 minutes to cool before restarting.
6. First-Response Checklist — Any Deye Error
- Note the exact error code AND the full fault name shown on the LCD — the name matters because some codes (like F42) mean different things on different models
- Check if the error appeared during load-shedding, heavy rain, extreme heat, or a dust storm — these are the most common Pakistan triggers
- For grid codes (F35, F42–F48): wait for the grid to stabilise — most self-clear automatically
- Power cycle the inverter: DC switch off → AC switch off → wait 1 minute → AC on → DC on. Deye's manual specifies a 1-minute wait
- For F01–F03, F08, F23, F24 (polarity, insulation, leakage, ground faults) — stop here, do NOT power on again. Call your installer immediately
- For F58 (BMS fault) — check the BMS cable, protocol setting and DIP switches before anything else
- If the inverter is within warranty, contact your authorized Deye dealer with the error code, model number, serial number, and a photo of the display
Frequently Asked Questions
Pehle: screen pe error code aur poora fault name dekho (F42 ka matlab model pe depend karta hai). Phir: DC switch band karo, AC switch band karo, 1 minute ruko, phir AC on karo, phir DC on. Agar code F35 hai (no grid): iska matlab grid gaya hua hai — load-shedding khatam hote hi inverter khud wapas on ho jata hai. Agar F01, F02 ya F03 hai: bilkul mat chalao — installer bulao.
It depends on your model. On single-phase Deye hybrids (SUN-3/5/6K-SG03LP1, SG04LP1), F42 is AC line low voltage — very common in Pakistan's summer evenings. On three-phase hybrids (SUN-5/6/8/10/12K-SG04LP3), F42 is a Parallel Version Fault (parallel inverters on mismatched firmware), and low voltage is F44/F46 instead. Always check the full fault name on the LCD.
F35 (No AC grid) is the most common Deye alarm in Pakistan — it simply means the grid dropped, which is load-shedding. The inverter resumes automatically when power returns. If F35 appears while the grid is live, check the breaker between inverter and grid and the AC connections.
F58 means the inverter lost communication with the lithium battery. Check the BMS cable and port — use the battery maker's cable, not a plain LAN cable — confirm the correct protocol and DIP switches, and confirm the battery is switched on. If 'BMS_Err-Stop' is active, the inverter stops until the link is fixed.
Yes — Inverex Nitrox inverters are built on the Deye platform, so the Nitrox F01–F64 code set is the Deye code set. The same code means the same thing on both brands. (Inverex Aerox/Veyron models are different — they use Voltronic numeric codes, not Deye F-codes.)